Catalog navigation
Main sections and subcategories
Open catalog

Laboratory jigger dyeing machine GT-D27

Laboratory jigger dyeing machine GT-D27

rating
0.00 so'm

  • Brand: GESTER
  • Product Code:ca3561e334a0
  • Availability:Pre-Order

Laboratory jigger dyeing machine GT-D27 is available from LABERA.UZ for laboratory, testing, medical and industrial applications in Uzbekistan.

Contact LABERA.UZ for specifications, pricing, lead time and a commercial quotation.

Technical Specifications
Lab Jigger Dyeing Machine Motor 2 sets of engines with a capacity of 120 W with precision control, equipped with a high-quality gearbox;
Lab Jigger Dyeing Sampling Machine Displayer Electronic touch screen of true color.
Time. Adjustable, signaling the end of the cycle.
Roller diameter 76 mm ~200 mm
Speed range and accuracy 0 10 m/min ± 0.001 m/min
Length of winding Automatically records, pre-installed, measured and monitored
power supply 220B, phase 1, 50Hz
Constructive design Modular design, convenient for precise production and extension of properties, specially designed structure with leading fabric, simple and smart, easy to install and dismantle;
Controller Industrial programmable logic controller (PLC), high reliability and improved interference protection; | Industrial programmable logic controller (PLC)
Dyeing imported SUS304 stainless steel, protection against rust, durability; staircase structure, consumes a solution of dyes of a small amount;
Jigger Dyeing Machine Lab Scales Work Interface color touch screen human-machine interface, ease of operation, programmable function, pre-configuration of painting technique for the client
Maximum roller diameter 200 mm
Massa about 45 kg
Model GT-D27
Power of the heater <1.2 kW
Tissue tension apply tension to the fabric, adjusting the different linear speeds of the two main rollers, and maintain constant tension, direct input of the tension value using a color touch screen, automatic speed adjustment;
Liquor volume about 1.8 litres
Variable direction Automatic change of direction depending on the length of the tissue and the number of cycles.
Counting Tracks and cycles are counted automatically.
Constant tissue velocity The use of advanced electronic coding technology for accurate control of tissue speed, maintaining a constant tissue speed in real time and usability.
Sizes. 910mm×720mm×900mm (D×Sh×V)
Distance of the main roller 380 mm
Stopping mode The number of stops can be set in advance.
Cooling and heating mode one set of cooling coil, electric heating, digital automatic temperature control system.
Cycle mode of dyes solution automatic stirring, maintaining uniformity of the solution of dyes;
Drive system equipped with 2 sets of single-phase engine 50 Hz, 120 W with precision control and gearbox, initiative control separately for reception and release of the roller.
Heating temperature and accuracy room temperature 98°C, ±2°C
Roller width ≤350 mm
Electrical load about 1.5 kW

Write a review

Note: HTML is not translated!
    Bad           Good