Catalog navigation
Main sections and subcategories
Open catalog

Tester of dry microbial penetration GT-RA14

Tester of dry microbial penetration GT-RA14

rating
0.00 so'm

  • Brand: GESTER
  • Product Code:0b896b55f96a
  • Availability:Pre-Order

Tester of dry microbial penetration GT-RA14 is available from LABERA.UZ for laboratory, testing, medical and industrial applications in Uzbekistan.

Contact LABERA.UZ for specifications, pricing, lead time and a commercial quotation.

Technical Specifications
E. UV intensity ≥ 80 μW/cm2
B. Biosafety indicators personnel safety, number of impact probe microbial colonies ≤ 10 CFU/time, number of slot probe colonies ≤ 5 CFU/time
V. Air channel tightness The air channel of the device is at a pressure of 500 Pa for 30 minutes, and the pressure drop is ≤ 10%. In the penetration part, there are no bubbles under the soap bubble test conditions.
H. Air purity class Class 100, i.e. dust content of particles ≥ 0.5 μm per litre of air ≤ 0.35
D.Shum the height of the countertop, 30 cm from the front window and 38 cm up, provided that the ambient noise is 55 dB, the arithmetic mean of the four directions is ≤ 58 dB(a)
J. Electrical resistance withstands voltage 1500V for 1 minute without breakdown
E. Lighting ≥ 680 lux Front window glass: tempered, resistant to ultraviolet radiation
Mechanical properties The countertop of the equipment must withstand a pressure of 25 kg without obvious subsidence, bending and other deformations.
H. Liquid collection tank is used to collect splashable liquid in the working area and is equipped with a drain valve.
Measurement 1500×765×1610 mm (W×D×V)
power supply 1 leg 220 V AC 50 Hz
Model GT-RA14
Desktop Marble slab
Desktop size 1360×690×520mm (SH×D×V)
Vibration mode Pneumatic ball vibrator
Vibration force 650 N
Standards YY/T0506.2 Surgical sheets, gowns and suits with clean air for patients, medical personnel and equipment. Part 2. Operational requirements and test methods; YY/T0506.5 Surgical sheets, bathrobes and suits with clean air for patients, medical personnel and equipment. Part 5. Test methods for penetration resistance of dry microbes; ISO 22612 Clothing for protection against infectious agents. Test method for resistance to penetration of dry microbes.
Vibration frequency 20,800 times/minute
Experimental container Experimental stainless steel container
hour pressure differential display (30/2) LCD display, pressure drop sensor Ge. The number displayed on the LCD display shows the loss of pressure in the filter, and the error of the pressure drop sensor is ≤ 5%.

Write a review

Note: HTML is not translated!
    Bad           Good