Catalog navigation
Main sections and subcategories
Open catalog

Fluke 8558A - Precision multimeter 8.5 bits

Fluke 8558A - Precision multimeter 8.5 bits

rating
0.00 so'm

  • Brand: Fluke
  • Product Code:F8558
  • Availability:Pre-Order

Fluke 8558A - Precision multimeter 8.5 bits is available from LABERA.UZ for laboratory, testing, medical and industrial applications in Uzbekistan.

Contact LABERA.UZ for specifications, pricing, lead time and a commercial quotation.

Technical Specifications
Weight: 9.8 kg.
Possibility of calibration/self-diagnosis Yes, internal and external calibration support, self-testing.
Dimensions: 431 × 88 × 475 mm (no handles), 440 × 88 × 510 mm (with handles).
Humidity range during tests <90% at +5 °C - +40 °C; <95% at 0 °C - +70 °C (without condensation).
Measurement/test range DC Voltage: 100 mV – 1000 V AC Voltage: 10 mV – 1000 V (1 Hz – 10 MHz) DC Current: 10 μA – 2 A AC Current: 10 μA – 2 A (1 Hz – 100 kHz) Resistance: 1 Ω – 10 GΩ Frequency: up to 100 MHz Capacitance: 1 nF – 100 mF Temperature: PRT support and thermal steam
Test temperature range Operating temperature: +5 °C - +40 °C.
Test frequency/speed range 1 Hz – 10 MHz (AC Voltage), 1 Hz – 100 kHz (AC Current), up to 100 MHz (frequency).
Measured/controlled parameters High-precision measurement of direct and alternating voltage, direct and alternating current, resistance, frequency, temperature, capacity, as well as signal digitization modes (Digitize V/I) with high speed.
Interfaces and exits: USB, Ethernet, GPIB, port for external triggers, USB flash drive connector.
Protection class / safety of operation CAT I 1000 V, CAT II 300 V, compliance with IEC61010.
Number and type of sensors Built-in circuits measuring voltage, current, resistance; support for external temperature sensors (PRT, thermocouples).
Completement Fluke 8558A, network cable, manual, measurement cable, software.
Maximum load/force
Work chamber/test table material
Test method / principle of operation Precision digital multimeter with 8.5-bit ADC, integrating measurement method, signal digitization function and built-in filters.
Availability of automatic mode / programmable cycles Yes, support for automated scripting via SCPI commands.
Availability of memory / data storage Up to 15 million measurements, export to CSV.
Work chamber size/test table size Approximately 300 x 300 mm (platform).
Measurement error/accuracy DCV: ±(4.0 μV/V reading + 0.06 μV/V range) ACV: ±(80 μV/V + 10 μV/V) Resistance: ±(10 μΩ/Ω + 0.6 μΩ/Ω) DCI: ±(10 μA/A + 5 μA/A) ACI: ±(300 μA/A + 100 μA/A) Frequency: ±0.5 μHz/Hz)
Software/PC Compatibility: Compatible with MET/CALTM, Fluke 8508A and Keysight 3458A emulation.
Heating system
Cooling/ventilation system Built-in passive and active cooling for stability.
Lubrication/media supply system
Deformation rate / heating-cooling rate
Country of production: China
Type of display/indication Color graphic display with trend modes, histograms and FFT.
Type of test drive
Control type: Digital, touch, computer (via GPIB, USB, Ethernet interfaces).
Power supply 100–120 / 200–240 V AC, 50/60 Hz.

Write a review

Note: HTML is not translated!
    Bad           Good